D+H UK

CPS-M Series   SHEV control panel - modular

CPS-M1-020-B

  • Power supply of connected drives with up to 20 A total current consumption

  • Tested and certified according to ISO 21927‑9, VdS 2581, VdS 2593, VdS 2344, DIN EN 12101‑10 and EN 62368-1:2014 + A11:2017, fulfils the building authority requirements in accordance with DIN 18232-9

  • Supply connection and communication using integrated plug connectors

  • Customisable, programmable control panel functions

  • Freely selectable line/group assignment

  • Sleek menu guidance using a 3.5" Full Colour Touch Panel, through which the system states of the individual modules can be visually observed (optional)

  • TMA trigger module: 2 independent lines to connect up to 10 SHEV operation panels each and 30 fire detectors

  • Actuator module (AM-B): 2 independent groups for connecting drives, each with a total maximum current of 10 A

Approvals / Certificates

Find out about permission details from your D+H Partner.

Content of this page:

Designs and technical data

CPS-M1-020-0202-B CPS-M1-020-0202-B-WD CPS-M1-020-0204-B CPS-M1-020-0204-B-WD CPS-M1-020-0404-B CPS-M1-020-0404-B-WD CPS-M1-020-0606-B CPS-M1-020-0606-B-WD
Supply 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA 230 V AC / 50 Hz / 530 VA
Stand-by power 7.5 W 7.5 W 7.5 W 7.5 W 7.5 W 7.5 W 7.5 W 7.5 W
Output 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A 24 V DC / 20 A
Ripple < 50 mVss < 50 mVss < 50 mVss < 50 mVss < 50 mVss < 50 mVss < 50 mVss < 50 mVss
Mode of operation monitoring Pulse operation Pulse operation Pulse operation Pulse operation Pulse operation Pulse operation Pulse operation Pulse operation
Mode of operation Alarm / Ventilation Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle Short-time duty 30 % duty cycle
Type of protection IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Temperature range -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C -5 °C … +40 °C
Number of TMA 1 1 1 1 2 2 3 3
Number of AM-B 1 1 2 2 2 2 3 3
Show more information
Request & 
Compare

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list
Request Request Request Request Request Request Request Request

Batteries must be ordered separately.

Instruction for use
7.25 MB
Tender documents
CPS-M1-020-0202-B
CPS-M1-020-0202-B-WD
CPS-M1-020-0204-B
CPS-M1-020-0204-B-WD
CPS-M1-020-0404-B
CPS-M1-020-0404-B-WD
CPS-M1-020-0606-B
CPS-M1-020-0606-B-WD