Performance features




- Can be used for openings for smoke exhaust; D+H Euro SHEV in accordance with EN 12101‑2; and for daily ventilation
- Perfectly suited for profile integrated and surface mounted installation
- Low running noises thanks to the innovative acoustic decoupling of the drive components
- Universal bracket sets for installation of all commonly available profile systems
- Flexible overall lengths for customised strokes
- Available in all RAL colours
- Can be used for virtually all window opening types thanks to the left and right drive
- Integrated ACB (Advanced Communication Bus) bus interface with Modbus RTU protocol
- The drive is integrated directly via open bus communication through the ACB (Advanced Communication Bus), e.g. in a building management system
Technical Data
Supply | 24 V DC / ±15 % / 1 A |
---|---|
Force of pressure | 250 N |
Tensile force | 250 N |
Nominal locking force ** | 1500 N |
Service life | 20000 double strokes * |
OPEN running speed | 6.7 mm/s |
OPEN running speed - SHEV | 15 mm/s |
CLOSED running speed | 6.7 mm/s |
Type of protection | IP 32 |
Emission sound pressure level | LpA ≤ 35 dB(A) |
Temperature range | -15 °C (-5 °C ***) … +75 °C |
Housing | Aluminium |
Surface | Powder-coated |
Colour | White aluminium (~ RAL 9006) |
Connection | 2.5 m silicone cable |
W x H x D | 635 x 30 x 39 mm |
** Depending on the mounting, *** in accordance with VdS 2580
Designs
Type | Art. No | Stroke | Weight | Remark |
---|---|---|---|---|
CDC-0252-0800-1-ACB M1-R | 26.102.05 | 800 mm | 1.6 kg | Right type |
CDC-0252-0800-1-ACB M1-L | 26.102.10 | 800 mm | 1.6 kg | Left type |
CDC-0252-0800-1-ACB M2-R | 26.102.06 | 800 mm | 1.6 kg | Right type |
CDC-0252-0800-1-ACB S1-L | 26.102.11 | 800 mm | 1.6 kg | Left type |
CDC-1-ACB | 26.100.00 | Variable equipment possible |
Brackets are not included and have to be ordered separately.
Potential drive options







Approvals / Certificates


These products are also available with the following approvals:



Find out about permission details from your D+H Partner.
Documents
CDC-0252-0700-1-ACB-L - CDC left chain drive 700mm stroke (694.58KB) | | | |
CDC-0252-0700-1-ACB-R - CDC right chain drive 700mm stroke (738.4KB) | | | |
CDC-0252-0800-1-ACB-L - CDC left chain drive 800mm stroke (717.17KB) | | | |
CDC-0252-0800-1-ACB-R - CDC right chain drive 800mm stroke (715.03KB) | | | |
CDC-0252-0900-1-ACB-L - CDC left chain drive 900mm stroke (754.37KB) | | | |
CDC-0252-0900-1-ACB-R - CDC right chain drive 900mm stroke (751.86KB) | | | |
CDC-0252-1000-1-ACB-L - CDC left chain drive 1000mm stroke (787.68KB) | | | |
CDC-0252-1000-1-ACB-R - CDC right chain drive 1000mm stroke (789.19KB) | | | |
CDC-0252-1100-1-ACB-L - CDC left chain drive 1100mm stroke (821.04KB) | | | |
CDC-0252-1100-1-ACB-R - CDC right chain drive 1100mm stroke (825.73KB) | | | |
CDC-0252-1200-1-ACB-L - CDC left chain drive 1200mm stroke (858.54KB) | | | |
CDC-0252-1200-1-ACB-R - CDC right chain drive 1200mm stroke (863.01KB) | | | |
CDC-0252-1300-1-ACB-L - CDC left chain drive 1300mm stroke (898.83KB) | | | |